3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch

WENZHOU JUNKE ELECTRIC CO., LTD.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Fast Transfer Response: Respond time is 0.05s for seamless power switching.
  • High Current Capacity: Rated current ranges from 100A to 3200A.
  • Robust Protection Grade: Shell protection grade IP55 with steel plate material.
  • Comprehensive Certifications: Certified with CCC, CE, and ISO9001 standards.
  • Long Mechanical Life: Mechanical life up to 8000 operations.
  • Intelligent Control Features: Supports remote control, adjustment, communication, and measurement.
  • Wide Application Range: Ideal for power plants, hospitals, and emergency lighting.
  • 5-Year Warranty: Provides 5 years of warranty coverage.

Product Images of 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch

3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch pictures & photos
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
  • 3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
    3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch

Find Similar Products

Product Description

630A Generator Transfer Switch ATS
What dual power automatic transfer switch?

Dual-power automatic transfer switch is microprocessor, which is used to start and switch between grid power and grid power or between grid power and generator power supply in power grid system. It can supply power continuously. Series of dual power supply, when the common use of sudden failure or power outage, through the dual power automatic transfer switch, automatically put into the standby power supply (under small load standby power supply can also be supplied by generators), so that the equipment can still operate normally. The most common are elevators, fire protection, monitoring, lighting and so on.
When the generator set is used as emergency lighting power supply, the start-up time and power conversion time of the generator should not exceed 15s. Double power automatic switching switch should choose "city power - generator conversion" special type.

Dual-power automatic transfer switch has the functions of short circuit and overload protection, over-voltage, under-voltage, phase-gap automatic conversion and intelligent alarm, automatic conversion parameters can be set freely outside, and intelligent protection of operating motor. When the fire control center gives a control signal to the intelligent controller, two circuit breakers enter the sub-unit. In the gate state, the computer network interface is reserved for the realization of remote control, remote adjustment, remote communication, remote measurement and other four remote functions.
Rated Current(Ith)   80A 100A 125A 160A 250A 400A 630A 800A 1000A 1250A 1600A
Rated insulation voltage(Ui) 750V 1000V
Rated concussion withstand voltage(Uimp) 8KV 12KV
Rated working voltage(Ue) AC440V
Rated working current(Ie) AC-31A 80 100 125 160 250 400 630 800 1000 1250 1600
AC-35A 80 100 125 160 250 400 630 800 1000 1250 1600
AC-33A 80 100 125 160 250 400 630 800 1000 1250 1600
Rated connection capacity 10le
Rated breaking capacity 8le
Rated limited short-circuit current(ls) 50kA 70kA 100kA 120kA
Rated short-time withstand current(ls) 7kA 9kA 13kA 26kA 50kA
Transfer I-II or II-I 0.45s 0.6s 1.2s
Control Power voltage DC24V. 48V. 110V.       AC220V
Electrical consumption  
Rated frequency Start 300W 325W 355W 400W 440W
Normal 55W 62W 74W 90W 98W
Weight(kg) 4 pole   7.2 7.5 7.5 8.8 9.0 16.5 17 32 36 40 43
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch


3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch

3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch
3p Three Phase Split Phaseterminal off Grid Power Generator Automatic Transfer Switch

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR243177". Items marked "verified" are certified.

Watch Video
Watch Video
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.

About Our Factory & Business Background

Address
Tangaozhu West Village Liushi Yueqing Zhejiang
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CIF, DDP, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Swtich, Power Capacitor, Air Circuit Breaker, Single Meter Socket, Online Soft Starter, Power Factor Correction Device, Energy Meter, Distribution Panel, AC Contactor, Moulded Case Circuit Breaker

Our Industry Experience & Global Business Record

Export Year
2010-10-01
Main Markets
South America, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia

FAQ

What is the response time for power transfer?
The respond time is 0.05s.
What is the rated current range?
The rated current ranges from 100A to 3200A.
What certifications does the product have?
The product is certified with CCC, CE, and ISO9001.
What is the mechanical life of the switch?
The mechanical life is 8000 operations.
What is the shell protection grade?
The shell protection grade is IP55.
What is the warranty period?
The warranty period is 5 years.
What are the main application scenarios?
It is suitable for power plants, hospitals, elevators, fire protection, monitoring, and lighting.
What is the average lead time?
Peak season lead time is one month, and off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now