Photovoltaic Transfer Unity Power Transfer Switch No Interrupt Power DIN Rail UPS
Contact Supplier
Product Highlights
- Zero Interruption Transfer: Responds in 0.008 seconds to ensure no power loss during switching.
- DIN Rail Compact Design: Small size allows for easy DIN rail installation in various settings.
- Dual Output Capability: Supports dual output types for flexible power distribution.
- High Current Rating: Rated current of 125A with a working current of 100A for heavy loads.
- Robust Steel Construction: Steel plate shell with IP55 protection grade for durability.
- Wide Application Range: Suitable for power plants, hospitals, and on-grid/off-grid solar systems.
- Multi-Certification Compliance: Certified with CCC, CE, and ISO9001 standards for quality assurance.
- Long Mechanical Life: Engineered for 8000 mechanical operations and 3000 electric operations.
Product Attributes
- Customization
- Available
- Warranty
- 5 Year
- Brand
- OEM
- Model NO.
- JKQ1-125A 2P PV
- Operation
- Electric
- Certification
- CCC, CE, ISO9001
- Type
- Integrated automatic transfer switch
- Poles
- 2P
- Output type
- Dual
- Respond Time
- 0.008second
- Application Range
- Power Plant,Hospital
- Shell Protection Grade
- IP55
- Shell Material
- Steel Plate
- Current
- 100A
- Pole
- Rstn
- Mechanical Life
- 8000
- Class
- Circuit Breaker
- Rated Current
- 125A
- Electric Life
- 3000
- Operate
- Asco Transfer Switch Manual
- ATS Wiring Diagram
- Diesel Generator
- Use Range
- Ongrid/off Grid Solar Panel
- Transport Package
- Paper /Wooden Pallet
- Specification
- RoHS package
- Trademark
- JUNKE
- Origin
- Zhejiang Yueqing
- HS Code
- 85385000
- Production Capacity
- 15000PCS
Product Images of Photovoltaic Transfer Unity Power Transfer Switch No Interrupt Power DIN Rail UPS
Find Similar Products
Product Description
125A 2P 0.008S three phase Photovoltaic transfer unlity power automatic transfer switch
1. no interrupt power
2.grid to solar panel inverter or photovoltaic panel
3. small size , din rail install
A transfer switch is an electrical switch that switches a load between two sources. Some transfer switches are manual, in that an operator effects the transfer by throwing a switch, while others are automatic and trigger when they sense one of the sources has lost or gained power.
An Automatic Transfer Switch (ATS) is often installed where a backup generator is located, so that the generator may provide temporary electrical power if the utility source fails.
Operation of a transfer switch
As well as transferring the load to the backup generator, an ATS may also command the backup generator to start, based on the voltage monitored on the primary supply. The transfer switch isolates the backup generator from the electric utility when the generator is on and providing temporary power. The control capability of a transfer switch may be manual only, or a combination of automatic and manual. The switch transition mode (see below) of a transfer switch may be Open Transition (OT) (the usual type), or Closed Transition (CT)).
For example, in a home equipped with a backup generator and an ATS, when an electric utility outage occurs, the ATS will tell the backup generator to start. Once the ATS sees that the generator is ready to provide electric power, the ATS breaks the home's connection to the electric utility and connects the generator to the home's main electrical panel. The generator supplies power to the home's electric load, but is not connected to the electric utility lines. It is necessary to isolate the generator from the distribution system to protect the generator from overload in powering loads in the house and for safety, as utility workers expect the lines to be dead.
When utility power returns for a minimum time, the transfer switch will transfer the house back to utility power and command the generator to turn off, after another specified amount of "cool down" time with no load on the generator.
A transfer switch can be set up to provide power only to critical circuits or to entire electrical (sub)panels. Some transfer switches allow for load shedding or prioritization of optional circuits, such as heating and cooling equipment. More complex emergency switchgear used in large backup generator installations permits soft loading, allowing load to be smoothly transferred from the utility to the synchronized generators, and back; such installations are useful for reducing peak load demand from a utility.
Types
Open transition
An open transition transfer switch is also called a break-before-make transfer switch. A break-before-make transfer switch breaks contact with one source of power before it makes contact with another. It prevents backfeeding from an emergency generator back into the utility line, for example.[1] One example is an open transition automatic transfer switch (ATS). During the split second of the power transfer the flow of electricity is interrupted. Another example is a manual three position switch or circuit breaker, with utility power on one side, the generator on the other, and "off" in the middle, which requires the user to switch through the full disconnect "off" position before making the next connection.
Closed transition[edit]
A closed transition transfer switch (CTTS) is also called a make-before-break transfer switch.
A typical emergency system uses open transition, so there is an inherent momentary interruption of power to the load when it is transferred from one available source to another (keeping in mind that the transfer may be occurring for reasons other than a total loss of power). In most cases this outage is inconsequential, particularly if it is less than 1/6 of a second.
There are some loads, however, that are affected by even the slightest loss of power. There are also operational conditions where it may be desirable to transfer loads with zero interruption of power when conditions permit. For these applications, closed transition transfer switches can be provided. The switch will operate in a make-before-break mode provided both sources are acceptable and synchronized. Typical parameters determining synchronization are: voltage difference less than 5%, frequency difference less than 0.2 Hz, and maximum phase angle between the sources of 5 electrical degrees. This means the engine driving the generator supplying one of the sources generally must be controlled by an isochronous governor.
It is generally required that the closed transition, or overlap time, be less than 100 milliseconds. If either source is not present or not acceptable (such as when normal power fails) the switch must operate in a break-before-make mode (standard open transition operation) to ensure no backfeeding occurs.
Closed transition transfer makes code-mandated monthly testing less objectionable because it eliminates the interruption to critical loads which occurs during traditional open transition transfer.
With closed transition transfer, the on-site engine generator set is momentarily connected in parallel with the utility source. This requires getting approval from the local utility company.
Typical load switching applications for which closed transition transfer is desirable include data processing and electronic loads, certain motor and transformer loads, load curtailment systems, or anywhere load interruptions of even the shortest duration are objectionable. A CTTS is not a substitute for a UPS (uninterruptible power supply); a UPS has a built-in stored energy that provides power for a prescribed period of time in the event of a power failure. A CTTS by itself simply assures there will be no momentary loss of power when the load is transferred from one live power source to another.
Soft loading
A soft-loading transfer switch (SLTS) makes use of a CTTS, and is commonly used to synchronize and operate onsite generation in parallel with utility power, and to transfer loads between the two sources while minimizing voltage or frequency transients
Static transfer switch (STS)
A static transfer switch uses power semiconductors such as Silicon-controlled rectifiers (SCRs) to transfer a load between two sources. Because there are no mechanical moving parts, the transfer can be completed rapidly, perhaps within a quarter-cycle of the power frequency. Static transfer switches can be used where reliable and independent sources of power are available, and it is necessary to protect the load from even a few power frequency cycles interruption time, or from any surges or sags in the prime power source.[6] [7]
Home use[edit]
Homes with standby generators may use a transfer switch for a few circuits or the whole home. Different models are available, with both manual and automatic transfer. Often small transfer switch systems use circuit breakers with an external operating linkage as the switching mechanism. The linkage operates two circuit breakers in tandem, closing one while opening the other. Manufacturers of transfer switches can provide installation guides to select the size of switch and provide recommended installation procedures.






About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR243177". Items marked "" are certified.
Company Profile
We are the professional manufacturing automatic transfer switch, air circuit breaker power capacitor ANSI meter socket and bypass online soft starter, starter panel and low high voltage switchgear panel indoor vacuum circuit breaker, outdoor SF6 circuit breaker, load break switch with automatic controller, auto transfer switch panel and so on
1. Who we are
Junkeis dynamic company established in 1992, who specializes in research and design, manufacturing, and distribution of low high voltage switchgear panel
2 why choose us
We have our own facilities for R& D, Production, Sales & Market, and Customer Support, specializing in the design, manufacture and delivery of customized solution. Equipped with all kinds of professional instruments and testing equipment, combined the professional standard of product testing methods, now we has an annual output of 5, 000, 000 or more products.
3 Junke Mission, vision values
Junke mission is to provide reliable, accurate and customized current transformer solution
Junke vision is leading automatic transfer switch and reactive compensate solution provider
Values Enthusiastic by our work, we offer a quality personal and close service to our customers
Some products have been approved by CE and IEC certificates.
Help client research electric souce for all panel. Control quality door to door to all country of world.
https://junkeelectric.en.made-in-china.com
About Our Factory & Business Background
- Address
- Tangaozhu West Village Liushi Yueqing Zhejiang
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, CIF, DDP, EXW
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays - Nearest Port
- NINGBO, SHANGHAI, QINGDAO
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2010-10-01
- Main Markets
- South America, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia
FAQ
- What is the response time for power transfer?
- The response time is 0.008 seconds, ensuring no interrupt power during the switch.
- What certifications does this transfer switch have?
- It is certified with CCC, CE, and ISO9001.
- Is this product customizable?
- Yes, the brand is OEM, allowing for customization options.
- What is the warranty period for this device?
- The warranty period is 5 years.
- What is the rated current and working current?
- The rated current is 125A, and the working current is 100A.
- What is the shell material and protection grade?
- The shell is made of steel plate with an IP55 protection grade.
- What are the typical applications for this switch?
- It is suitable for power plants, hospitals, and on-grid/off-grid solar panel systems.
- What is the mechanical and electric life expectancy?
- The mechanical life is 8000 operations, and the electric life is 3000 operations.
Send your message to this supplier
People who viewed this also viewed
-
US$40.00-100.00 / Piece
-
US$10.00 / Piece
-
US$40.00 / Piece
-
US$40.00 / Piece
-
US$120.00-150.00 / Piece
Product Groups
- Single Phase Pad Mounted Transformer
- Load Center
- Ansi Meter Base
- Reactive Power Capacitor
- Automatic Transfer Switch
- Air Circuit Breaker
- Instrument and Meters
- Softstarter and Inverter
- pole transformer bushing changer
- sine wave inverter
- Hall Effect Current Sensor
- LV Current Transformers
Find Similar Products By Category
- Supplier Homepage
- Products
- Automatic Transfer Switch
- Photovoltaic Transfer Unity Power Transfer Switch No Interrupt Power DIN Rail UPS
Related Categories
Hot Searches
- Switch Box Factories
- Electric Switch Factories
- Level Switch Factories
- Power Switch Factories
- Automatic Power Switch
- Automatic Circuit Switch
- Automatic Transfer Switch For Generator
- Electric Transfer Switch
- Ats Switch For Generator
- Switch Bulkbuy