Customization: | Available |
---|---|
Type: | Hall Type |
Output Signal Type: | Analog Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
N1 series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method,
with a galvanic isolation between primary and secondary circuit.
It provides accurate electronic measurement of DC, AC or pulsed currents.
(Ta=25 ±5 ,RL=2KΩ,CL=10000PF)
Type |
N1-10A |
N1-20A |
N1-30A |
N1-40A |
N1-50A |
Unit |
Rated current(Ipn) |
10 |
20 |
30 |
40 |
50 |
A |
Measure range(Ip) |
20 |
40 |
60 |
80 |
80 |
A |
Rated output |
@Ip=±Ipn ±4±0.5% |
V |
||||
Supply voltage |
±12V,±15V |
V |
||||
Power Consumption |
≤25 |
mA |
||||
Zero offset voltage |
@Ip=0 ≤±30 |
mV |
||||
Offset voltage drift |
@ -40~+85 ≤±0.5 |
mV / |
||||
Linearity |
@Ip=0-±Ipn ≤0.1 |
%FS |
||||
Response time |
@50A/μ S,10%-90% ≤1 |
μS |
||||
Galvanic isolation |
@ 50HZ,AC,1min 2.5 |
KV |
Applications
·AC variable speed drives
·Static converters for DC motor drives
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Switched Mode Power Supplies (SMPS)
·Power supplies for welding applications
Mechanical dimension (for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
Directions for use
1.When the current will be measured goes through a sensor, the current will be measured at the output end. (Note: The false wiring may result in the damage of the sensor)
2.Custom design in the different rated input current and the output current are available.
Standards
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
General date
|
Value |
Unit |
Operating temperature (TA) |
-40 to +85 |
|
Storage temperature (TS) |
-40 to +125 |
|
Mass(approx) (M) |
12 |
g |