• 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit
  • 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit
  • 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit
  • 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit
  • 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit
  • 30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit

30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vacuum
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ZW32-30KV
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB
Voltage Transformer
220/110V Output
Current Transformer
630-3150A
Protect
Water Proof
Material
304 Stainless
Machenisam
Spring
Transport Package
Wooden Package
Trademark
JUNKE
Origin
Wenzhou
Production Capacity
1000PCS/Month

Product Description

30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker FTU Feeder terminal unit
Rated Voltage

a. Nominal system voltage-30,000volt
b. Rated maximum voltage -36000 volts.
c. Power frequency withstand voltage-70 KV
Rated frequency - 50 Hertz
a tolerance of ± 5 percent. Rated symmetrical making current is the same value as the
rated symmetrical interrupting current, with asymmetrical
relationships as defined in ANSI/IEEE C37.60.
Rated  Impulse Withstand Voltage - 170 KV.

DESIGN
30KV three phase class III recloser is in accordance with the standard ANSI/IEEE C37.60.
The recloser is designed to provide self-contained 30KV circuit protection with series trip,
solenoid operation and electronic control single break contact structure and fault interruption under
vacuum. The vacuum interrupters are in accordance with ANSI/IEEE C37.85.  The recloser is accordance with ANSI/IEEE C37.85. The recloser is  designed to sense line-to-ground, line-
to-line or three-phase fault currents and interrupt all three phases of the distribution circuit
simultaneously. The recloser is equipped with a electronic type ground feature. For fault target,
Automatic Circuit recloser will be provided with an indicator for detection of fault current on
individual phase or ground. If the Electronic Control cubicle of Reclosers or Recloser itself require
an auxiliary transformer, the manufacturer must provide the same at his cost. The recloser is
provided with in-built auxiliary transformer of required rating to provide power supply to the control
panel.

 

Rated voltage, kV

24 30 ,33,

Max. working voltage, kV

36

Rated current, not less than, A

630A / 1600A

Rated breaking current, not less than, kA

20

Electrical dynamic withstand current, kA

51

Operation times

30000

Heating withstand current (during 3 seconds/this parameter must not be as 1 sec) , not less than, kA

20

Open, close reserve, not less than  

- By rated current, Close-Open action 

- By breaking current, Close-Open action

 

30000

25

Breaking own period, not more than, ms

45

Full breaking period, not more than, ms

55

Close own period, not more than, ms

60

Testing voltage of lightning impulse, kV

190

1 min testing voltage by voltage with production frequency, kV

95

Cycle of recloser

O-0.02S-C-0.1S

Max amount of close and open cycle within 1 hour, not less than

100

Ambient environmental condition performance

Dedicated to work for outdoor and cold weather

Upper limit of ambient relative moisture when air temperature is at 25°C

            100%

 

Ambient environmental min temperature,°C (It must be approved by test)

-50

Ambient environmental max temperature,°C (It must be approved by test)

+55

Environmental condition, not less than

Above 1500 m from sea altitude

Protection degree of drive external main body

IP54

Penetration length of external insulating, mm, not less than

1700

Permissible environmental wind amount when no icing-not more than

40 m/s

Permissible environmental wind amount of wire iced period (Icing wall thickness is till 20 mm), not more than

15 m/s

24KV Outdoor Vacuum Circuit Breaker Installation dimensions:
30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit

How to wire with vacuum switch

Make sure the end -user follow below diagram to connect the junction box to BRZW32 vacuum switch. Junction box is self-power supply controller

Before employ switch for H.V.line, please make sure each cable connector is correct connection.

Please push each A.B.C phase switch button to check if connection in good condition. The proper work is each phase electric control is corresponding correct phase switch

30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit30kv 1250A Auto Circuit Recloser ACR with Automatic Controller Remote Operation Pole Mounted Vacuum Breaker Ftu Feeder Terminal Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now