Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of US$ 1000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
outdoor vacuum circuit breaker with feeder termianl unit FTU, DTU RTU
Rated Voltage
a. Nominal system voltage-24,000volt
b. Rated maximum voltage -36000 volts.
c. Power frequency withstand voltage-70 KV
Rated frequency - 50 Hertz
a tolerance of ± 5 percent. Rated symmetrical making current is the same value as the
rated symmetrical interrupting current, with asymmetrical
relationships as defined in ANSI/IEEE C37.60.
Rated Impulse Withstand Voltage - 170 KV.
DESIGN
24KV three phase class III recloser is in accordance with the standard ANSI/IEEE C37.60.
The recloser is designed to provide self-contained 24KV circuit protection with series trip,
solenoid operation and electronic control single break contact structure and fault interruption under
vacuum. The vacuum interrupters are in accordance with ANSI/IEEE C37.85. The recloser is accordance with ANSI/IEEE C37.85. The recloser is designed to sense line-to-ground, line-
to-line or three-phase fault currents and interrupt all three phases of the distribution circuit
simultaneously. The recloser is equipped with a electronic type ground feature. For fault target,
Automatic Circuit recloser will be provided with an indicator for detection of fault current on
individual phase or ground. If the Electronic Control cubicle of Reclosers or Recloser itself require
an auxiliary transformer, the manufacturer must provide the same at his cost. The recloser is
provided with in-built auxiliary transformer of required rating to provide power supply to the control
panel.
Rated voltage, kV |
24 30 ,33, |
|
Max. working voltage, kV |
36 |
|
Rated current, not less than, A |
630A / 1600A |
|
Rated breaking current, not less than, kA |
20 |
|
Electrical dynamic withstand current, kA |
51 |
|
Operation times |
30000 |
|
Heating withstand current (during 3 seconds/this parameter must not be as 1 sec) , not less than, kA |
20 |
|
Open, close reserve, not less than - By rated current, Close-Open action - By breaking current, Close-Open action |
30000 25 |
|
Breaking own period, not more than, ms |
45 |
|
Full breaking period, not more than, ms |
55 |
|
Close own period, not more than, ms |
60 |
|
Testing voltage of lightning impulse, kV |
190 |
|
1 min testing voltage by voltage with production frequency, kV |
95 |
|
Cycle of recloser |
O-0.02S-C-0.1S |
|
Max amount of close and open cycle within 1 hour, not less than |
100 |
|
Ambient environmental condition performance |
Dedicated to work for outdoor and cold weather |
|
Upper limit of ambient relative moisture when air temperature is at 25°C |
|
|
Ambient environmental min temperature,°C (It must be approved by test) |
-50 |
|
Ambient environmental max temperature,°C (It must be approved by test) |
+55 |
|
Environmental condition, not less than |
Above 1500 m from sea altitude |
|
Protection degree of drive external main body |
IP54 |
|
Penetration length of external insulating, mm, not less than |
1700 |
|
Permissible environmental wind amount when no icing-not more than |
40 m/s |
|
Permissible environmental wind amount of wire iced period (Icing wall thickness is till 20 mm), not more than |
15 m/s |
24KV Outdoor Vacuum Circuit Breaker Installation dimensions: