Single Phase Power Quality Hamonic Analyzer Calibrator

WENZHOU JUNKE ELECTRIC CO., LTD.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Harmonic Analysis: Tests 2nd to 51st harmonics, THD, and individual harmonic content with clear LCD display.
  • High Precision Accuracy: Voltage and current accuracy up to 0.1%, ensuring reliable measurements for field calibration.
  • Customizable Specifications: Supports customized accuracy classes, CT types, and measurement ranges to meet specific needs.
  • Portable and Battery Powered: Compact design (1.5kg) with 4-hour battery endurance for convenient on-site testing.
  • Robust Data Storage: Stores up to 1000 meter data records with 8MB internal memory for easy data management.
  • Wide Input Range: Handles AC 87~265V power supply and measures current from 0.1A to 1000A via clamp-on CT.
  • CE and CCC Certified: Meets international safety and quality standards with CE and CCC certifications.
  • Multi-Function Calibration: Calibrates voltage, current, power, and harmonics, supporting RS 232 communication.

Product Images of Single Phase Power Quality Hamonic Analyzer Calibrator

Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
Single Phase Power Quality Hamonic Analyzer Calibrator pictures & photos
Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
    Single Phase Power Quality Hamonic Analyzer Calibrator

Find Similar Products

Product Description

 
Single Phase Power Quality Hamonic Analyzer Calibrator
Harmonic analysis
Function description
1. Perform the 2nd ~ 51st harmonic analysis on the measured signal, and test the total harmonic distortion rate,
odd and even times and each harmonic content.(note: test the 2nd ~ 21st harmonics according to the national
standard)
2. Test and analyze three-phase voltage and current, respectively, show the harmonic content of each harmonic in
the form of corresponding light bar chart, and display the percentage of corresponding harmonic content
accordingly.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
Press "3 harmonic" key to enter the "harmonic" state, and after entering the interface, the interface below displays
15PEC-HA Single-phase energy meter field calibrator -- User manual
voltage, current and sorting three options; select voltage and press "F2" key, choose current and press "F3", select
sorting and press "F5", show the each harmonic content of current or voltage according to the operation, and the
biggest harmonic on the scale line is full scale. If the harmonic is very small, only parts per ten thousand, such as
maximum 0.06%, the percentage value of the highest scale is 0.06%, and the subtle harmonic is amplified, clear at
a glance.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
The instrument can test a total of 2nd ~ 51st harmonics, and show harmonic spectrum and give out the percentage
content of each harmonic. The 21st harmonic is used as an example in the following to calculate (the 51st harmonic
is calculated the same as the 21st harmonic)
Wherein:
Percentage content of each harmonic - refers to the percentage of the effective value of the 2nd ~ 21st harmonic
relative to the effective value of fundamental wave, defined as follows:
(of which i = 2, 3, 4 · · · · · · 21; Ui is the effective value of each harmonic, and U1 is the effective
value of fundamental wave.);
Harmonic order - refers to the multiples of fundamental wave frequency, relative to fundamental wave. If the
frequency of mains supply is 50Hz, the 2nd harmonic is 100Hz AC component, the 3rd harmonic is 150Hz AC
component and so on.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
Channel indicator -- the harmonic state of the channel currently tested.(six channels are
respectively:);
16PEC-HA Single-phase energy meter field calibrator -- User manual
Odd order harmonic distortion rate - refers to the percentage of the total effective value of odd harmonics relative
to the effective value of fundamental wave, defined as follows:
In case of
Then, odd aberration rate
Even order distortion rate - refers to the percentage of the total effective value of even harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the even order distortion rate
Then, the total harmonic distortion
Total harmonic distortion--refers to the percentage of the total effective value of harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the total harmonic distortion
17PEC-HA Single-phase energy meter field calibrator -- User manual
 
Single Phase Power Quality Hamonic Analyzer Calibrator
The scale line - the biggest harmonic is full.
Harmonic pollution to power grid is becoming more and more serious, so the harm caused by harmonics can not
be ignored, mainly reflected in:
1. Greatly increasing the chance of resonance in power grid, thus causing the risk of accidents arisen from very
high overcurrent or overvoltage;
2. Increasing additional loss, and reducing the efficiency of power generation, transmission and power equipment
and the equipment utilization;
3. Increasing the losses to electrical equipment (rotary motors, capacitors, transformers, etc.), accelerating the
insulation aging, and thus shortening the service life;
4. Enabling the relay protection and automatic device, computer systems, and a lot of electrical equipment to run
abnormally;
5. Leading to the metering and measuring instruments (such as: energy meter) not to give correct instructions or
measurement;
6. Interfering with the communication system, lowering down the quality of signal transmission, disturbing the
normal transmission signal, and even damaging the communications equipment.
General
Power supply AC 87~265V, 50~60Hz
Power consumption About 10VA
Ambient temperature -20ºC--+40ºC (accuracyassured)
Relative humidity (not condensing) 40%-90%
Dimension(D×W×H, mm) 249×154×58
Weight 1.5Kg
Warm-up time < 3 minutes
Battery endurance 4hours
LCD color display 5.7", 320×240 TFT
Communication port RS 232
Data storage 8 mega bite
Safety
Declaration of conformity CE conformed
Operation reference
Measuring range AC 30~265V
Intrinsic errors
 
  via clamp-on CT's via terminals
Voltage 0.1% 0.1%
Current 0.3% (0.1A~1000A)
Long term accuracy assured (1A~40A)
0.1% (0.1A~10A)
Power 0.3%
Long term accuracy assured (1A~40A)
0.1%
Active power 0.3%
Long term accuracy assured (1A~40A)
0.1%
 
0.1%
Reactive power 0.5% 0.3%
Harmonic 2nd ~51st 0.1%
Integrated virtual load Output current: 10A, power: 20VA
Others
Internal virtual load Output current: 20A, power: 20VA
Constant of pulse FL=3.6×104P/KWh FH=3.6×108P/KWh







 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR243177". Items marked "verified" are certified.

Watch Video
Watch Video
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.

About Our Factory & Business Background

Address
Tangaozhu West Village Liushi Yueqing Zhejiang
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CIF, DDP, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Swtich, Power Capacitor, Air Circuit Breaker, Single Meter Socket, Online Soft Starter, Power Factor Correction Device, Energy Meter, Distribution Panel, AC Contactor, Moulded Case Circuit Breaker

Our Industry Experience & Global Business Record

Export Year
2010-10-01
Main Markets
South America, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia

FAQ

What is the harmonic analysis range of this device?
The device performs harmonic analysis from the 2nd to the 51st harmonic, including total harmonic distortion and individual harmonic content.
What is the accuracy class for voltage and current measurements?
The accuracy class is 0.1% for voltage and 0.1% for current (long-term accuracy assured for 1A~40A).
Can the product specifications be customized?
Yes, the product is customizable, including accuracy classes, clamp-on CT ratings, and self-adjust CT options.
How long does the battery last during operation?
The battery endurance is approximately 4 hours, allowing for extended field use without immediate recharging.
What is the data storage capacity of the analyzer?
It can store up to 1000 meter data records with 8MB of internal memory.
What certifications does this product hold?
The product holds CE and CCC certifications, ensuring compliance with relevant safety and quality standards.
What is the typical lead time for orders?
Lead time is within 15 workdays during the off-season and about one month during the peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now