Single Phase Power Quality Hamonic Analyzer Calibrator

Product Details
Customization: Available
Application: Electromagnetic Instrument
Power: Electricity
Still deciding? Get samples of US$ 510/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2010-10-01
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
  • Single Phase Power Quality Hamonic Analyzer Calibrator
Find Similar Products

Basic Info.

Model NO.
PEH-1A
Certification
CE, CCC
Voltage Output
220V
Current Output
40A
Thermocouple (TC)
S
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Customized
Customized
Accuracy Classes
0.1
Clamp-on CT
100A
Self Adjust CT
5A
Measurement of Harmonics
2ND to 51st
Measured Results Can Be Stored
1000PC Meter Data
Power Supply
AC 87~265V
Power Consumption
10va
Data Storage
8 Mega Bite
Transport Package
Pallet
Specification
CE ROHS
Trademark
JUNKE
Origin
Zhejiang Yueqing
HS Code
902890100

Product Description

 
Single Phase Power Quality Hamonic Analyzer Calibrator
Harmonic analysis
Function description
1. Perform the 2nd ~ 51st harmonic analysis on the measured signal, and test the total harmonic distortion rate,
odd and even times and each harmonic content.(note: test the 2nd ~ 21st harmonics according to the national
standard)
2. Test and analyze three-phase voltage and current, respectively, show the harmonic content of each harmonic in
the form of corresponding light bar chart, and display the percentage of corresponding harmonic content
accordingly.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
Press "3 harmonic" key to enter the "harmonic" state, and after entering the interface, the interface below displays
15PEC-HA Single-phase energy meter field calibrator -- User manual
voltage, current and sorting three options; select voltage and press "F2" key, choose current and press "F3", select
sorting and press "F5", show the each harmonic content of current or voltage according to the operation, and the
biggest harmonic on the scale line is full scale. If the harmonic is very small, only parts per ten thousand, such as
maximum 0.06%, the percentage value of the highest scale is 0.06%, and the subtle harmonic is amplified, clear at
a glance.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
The instrument can test a total of 2nd ~ 51st harmonics, and show harmonic spectrum and give out the percentage
content of each harmonic. The 21st harmonic is used as an example in the following to calculate (the 51st harmonic
is calculated the same as the 21st harmonic)
Wherein:
Percentage content of each harmonic - refers to the percentage of the effective value of the 2nd ~ 21st harmonic
relative to the effective value of fundamental wave, defined as follows:
(of which i = 2, 3, 4 · · · · · · 21; Ui is the effective value of each harmonic, and U1 is the effective
value of fundamental wave.);
Harmonic order - refers to the multiples of fundamental wave frequency, relative to fundamental wave. If the
frequency of mains supply is 50Hz, the 2nd harmonic is 100Hz AC component, the 3rd harmonic is 150Hz AC
component and so on.
 
Single Phase Power Quality Hamonic Analyzer Calibrator
Channel indicator -- the harmonic state of the channel currently tested.(six channels are
respectively:);
16PEC-HA Single-phase energy meter field calibrator -- User manual
Odd order harmonic distortion rate - refers to the percentage of the total effective value of odd harmonics relative
to the effective value of fundamental wave, defined as follows:
In case of
Then, odd aberration rate
Even order distortion rate - refers to the percentage of the total effective value of even harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the even order distortion rate
Then, the total harmonic distortion
Total harmonic distortion--refers to the percentage of the total effective value of harmonics relative to the
effective value of fundamental wave, defined as follows:
In case of
Then, the total harmonic distortion
17PEC-HA Single-phase energy meter field calibrator -- User manual
 
Single Phase Power Quality Hamonic Analyzer Calibrator
The scale line - the biggest harmonic is full.
Harmonic pollution to power grid is becoming more and more serious, so the harm caused by harmonics can not
be ignored, mainly reflected in:
1. Greatly increasing the chance of resonance in power grid, thus causing the risk of accidents arisen from very
high overcurrent or overvoltage;
2. Increasing additional loss, and reducing the efficiency of power generation, transmission and power equipment
and the equipment utilization;
3. Increasing the losses to electrical equipment (rotary motors, capacitors, transformers, etc.), accelerating the
insulation aging, and thus shortening the service life;
4. Enabling the relay protection and automatic device, computer systems, and a lot of electrical equipment to run
abnormally;
5. Leading to the metering and measuring instruments (such as: energy meter) not to give correct instructions or
measurement;
6. Interfering with the communication system, lowering down the quality of signal transmission, disturbing the
normal transmission signal, and even damaging the communications equipment.
General
Power supply AC 87~265V, 50~60Hz
Power consumption About 10VA
Ambient temperature -20ºC--+40ºC (accuracyassured)
Relative humidity (not condensing) 40%-90%
Dimension(D×W×H, mm) 249×154×58
Weight 1.5Kg
Warm-up time < 3 minutes
Battery endurance 4hours
LCD color display 5.7", 320×240 TFT
Communication port RS 232
Data storage 8 mega bite
Safety
Declaration of conformity CE conformed
Operation reference
Measuring range AC 30~265V
Intrinsic errors
 
  via clamp-on CT's via terminals
Voltage 0.1% 0.1%
Current 0.3% (0.1A~1000A)
Long term accuracy assured (1A~40A)
0.1% (0.1A~10A)
Power 0.3%
Long term accuracy assured (1A~40A)
0.1%
Active power 0.3%
Long term accuracy assured (1A~40A)
0.1%
 
0.1%
Reactive power 0.5% 0.3%
Harmonic 2nd ~51st 0.1%
Integrated virtual load Output current: 10A, power: 20VA
Others
Internal virtual load Output current: 20A, power: 20VA
Constant of pulse FL=3.6×104P/KWh FH=3.6×108P/KWh







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier