25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump

Product Details
Customization: Available
Application: Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 1/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2010-10-01
  • 25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump
  • 25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump
  • 25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump
  • 25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump
  • 25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump
Find Similar Products

Basic Info.

Model NO.
JKR2-18KW
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Material
Aluminum Alloy
Conmunication
RS485/RS232 PLC
Input Voltage
380V.440V
Adaptive Motor
Squirrel-Cage Three-Phase Asynchronous Motor
Starting Times
It Is Recommended Not to Exceed 20 Times Per Hour.
Stop Mode
Online /Bypass
Output Power
7.5kw-680kw
Output Curren
22A ~1200A
Cooling Mode
DC/AC Fan
Control
Voltage Control
Current
Current Control
Transport Package
Wooden Package
Specification
RoHS package
Trademark
OEM
Origin
Zhejiang Yueqing
HS Code
8537101990
Production Capacity
10000PCS/Month

Product Description

25HP 18KW 380v 60hz bypass soft starter  for water pump
variable frequency drives (VFD) VS soft starters. 
In previous articles, we have talked about variable frequency drives (VFD) and soft starters. If you need a refresher on the detailed working of either a VFD or Soft Starter be sure to look back at those articles by clicking the links below.
What is a VFD?
What is a Soft Starter?
The devices are similar in that they control the starting and stopping of industrial motors but have different characteristics that we will identify in this article.
https://youtu.be/_ZztDN5XX5o
The Basics
A soft starter is generally used in applications where there is a large inrush of current that could damage a motor while a VFD controls and can vary the speed of a motor.
In this article, we will look at:
- Internal workings of these devices
- How to determine which device you might want
- Look at some applications to better understand their differences
25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump

Let's first talk about the internal working of these two devices.
Internal Workings of a Soft Starter
A typical three-phase soft starter uses six Thyristors or Silicon Controlled Rectifiers, oriented in an anti-parallel configuration to start the electric motors smoothly.
A Thyristor is made up of 3 parts:
- Logic gate
- Cathode
- Anode
When an internal pulse is applied to the gate, it allows current to flow from Anode to Cathode which then sends current out to our motor.
When the internal pulses do not apply to the gate, the SCRs (Silicon Controlled Rectifier) are in the OFF state and therefore they restrict the current to the motor.
25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump

These internal pulses limit the applied voltage to the motor slowing down inrush current.
The pulses are sent based on ramp time so the current will be slowly applied to the motor. The motor, attached to the soft starter, will start up at a nice smooth current and top out at the preset maximum speed.
The motor will stay at that speed until we stop the motor where the soft starter will ramp down the motor in a very similar way as the ramp up.
25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump

Internal Workings of a VFD
VFDs have three main components:
- Rectifier
- Filter
- Inverter
The Rectifier acts like Diodes, takes the incoming AC voltage and changes it to DC voltage.
Next, the Filter uses Capacitors to clean the DC voltage making it a smoother incoming power.
Finally, the Inverter uses transistors to convert the DC voltage and sends the motor a frequency in Hertz. This frequency drives the motor to a specific RPM.
We can set the ramp up and down times just like in a soft starter.
25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump

VFD or Soft Starter? Which One should I Choose?
From what we just covered, we can see that a VFD is basically a soft starter with speed control. So how do we know which device is needed for our application?
The decision on which device you choose comes down to how much control your application requires. There are other factors that we should consider in our decision.
1. Speed Control
If your application requires a large inrush of current but does not require speed control, then a soft starter is the best option. 
If speed control is required, then a VFD is a must. 
2. Price
Price can be a determining factor in a lot of real-world applications. Since a soft starter has fewer control features, the price is lower than a VFD.
3. Size
Finally, if the size of our device is a determining factor, soft starters are generally smaller than most of the VFDs.
Now, let's look at some real-world applications to help us see the difference between a VFD and a Soft Starter.
Application Example of VFDs and Soft Starters 
1. Water Treatment Facility
The first application will be a wastewater pump. A water treatment plant typically has a constant flow of water coming into the plant. Let's assume the demand for water exiting the plant is constant with the supply entering the plant.
Which device would be the best option?
That's right! A soft starter would be a great choice because in this application when starting the water pump there would be a large inrush of current on our motor that our soft starter could handle and gradually ramp up the pump.
Since the demand for water exiting the plant is the same as supply into the plant the speed of our pump would not vary.
However, if the demand for water exiting the plant raises or lowers, we would want to vary our speed making a VFD a better choice for the application.

2. Cooling Fan System
The next application we will look at is a cooling fan.
In this scenario, a cooling fan will turn on when the plant air temperature hits a high-temperature set-point.
Once the set-point is reached, the cooling fan will slow down to maintain the air temperature unless it drops below a low-temperature setpoint, where it will shut off.
However, if the temperature continues to rise and pass the high-temperature setpoint, the fan will need to move faster.
Which device would work best in this situation?
That's right! A VFD would be better than a soft starter because the speed of the fan will need to vary.
If our scenario was only turning the fan on or off based on temperature and not changing speed, then a soft starter would be a better option.
25HP 18kw 380V 60Hz Bypass Soft Starter for Water Pump


Summary
In closing, a VFD and a Soft Starter can do similar functions when it comes to ramp up or down a motor.
The main difference between the two is that a VFD can vary the speed of a motor while a soft starter only controls the starting and stopping of that motor.
When faced with an application, price and size are in the favor of a soft starter. A VFD is the better choice if speed control is required.
The good news is that if an existing application has a soft starter in place and speed control is later determined to be a requirement, a VFD can easily replace a soft starter. The opposite is true as well, a soft starter can replace a VFD.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier