• Fkn12A Indoor AC High Voltage Load Break Switch with Fuse
  • Fkn12A Indoor AC High Voltage Load Break Switch with Fuse
  • Fkn12A Indoor AC High Voltage Load Break Switch with Fuse
  • Fkn12A Indoor AC High Voltage Load Break Switch with Fuse
  • Fkn12A Indoor AC High Voltage Load Break Switch with Fuse
  • Fkn12A Indoor AC High Voltage Load Break Switch with Fuse

Fkn12A Indoor AC High Voltage Load Break Switch with Fuse

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Fuse
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
FKN12A-630A
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB
Using Range
Outdoor
Insulate Medium
Vacuum
Voltage
12/24/36kv
Mechanisam
Permanent Magnet
Transport Package
Wooden Package
Trademark
JUNKE
Origin
Wenzhou
Production Capacity
1000PCS/Month

Product Description

FKN12A-12D 12KV Indoor High Voltage Load Break Switch

Main purpose
FKN12A-12DCompressed air load switch, FKRN12A-12D series of compressed air load switch - fuse for 12kV and below three-phase power distribution system, as transformers, cables, overhead lines and other electrical equipment, control and protection purposes; especially suitable for urban and rural power network terminal substation and box-Model substation. And applies to ring, dual power supply unit of radiation control and protection.
FKN12A-12DSeries pressuring gas division and the load current load switch and overload currents.
FKRN12A-12D series of compressed air load switch - fuse to division and load current, overload current, short-circuit breaking current.

Use of environmental conditions

Ambient air temperature    Limit +40°C  Lower -25°C
Above sea level1000m.
Relative humidity: daily average is less than 95%, on average less than 90%;

Seismic intensity of not more than 8 degrees;

No fire, explosion, chemical corrosion and severe vibration in the workplace; 
Contamination level:II.

Structural characteristics

Load switch, grounding switch, fuse and institutions in a framework, it can be flexibly combined, compact structure, small size and ease of installing;
Fracture for the direct-acting Model layout, dynamic and thermal parameters of high current, one-time to complete the operation;
Static contact with insulation cover, so that the structure of ring counters implemented in isolation, eliminating the white insulated partition, fracture insulation flapper to prevent cabinet arc short circuit;
 The valve has a unique structure, the load switches gate, the door automatically isolate the fracture, protective and good;
Load switches and earthing switches, fuses reliable mechanical lock between the devices meet the "Five Anti" requirements;
 With manual operation and the operation of AC and DC electric power operations in two forms, easy to implement power system of the "three remote" requirements.

Technical data
Fkn12A Indoor AC High Voltage Load Break Switch with FuseFkn12A Indoor AC High Voltage Load Break Switch with FuseOutline and installation dimension