15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

WENZHOU JUNKE ELECTRIC CO., LTD.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Smooth Motor Control: Uses six thyristors to limit inrush current and ramp up/down motor speed smoothly.
  • Wide Power Range: Supports output power from 7.5kw to 680kw for various industrial needs.
  • Versatile Applications: Ideal for water treatment, cooling fans, elevators, and textile machinery.
  • Compact Design: Generally smaller in size compared to Variable Frequency Drives (VFDs).
  • Cost Effective: Lower price point than VFDs due to fewer control features.
  • Flexible Communication: Features RS485/RS232 PLC communication for easy integration.
  • Robust Cooling: Equipped with DC/AC fan cooling mode for stable operation.
  • Durable Material: Constructed with high-quality aluminum alloy for longevity.

Product Images of 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel pictures & photos
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
  • 15HP 11kw 380V 50Hz AC Soft Starter for Control Panel
    15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

Find Similar Products

Product Description

40HP 30kw three phase bypass soft stater with bypass contactor 
variable frequency drives (VFD) VS soft starters. 
In previous articles, we have talked about variable frequency drives (VFD) and soft starters. If you need a refresher on the detailed working of either a VFD or Soft Starter be sure to look back at those articles by clicking the links below.
What is a VFD?
What is a Soft Starter?
The devices are similar in that they control the starting and stopping of industrial motors but have different characteristics that we will identify in this article.
https://youtu.be/_ZztDN5XX5o
The Basics
A soft starter is generally used in applications where there is a large inrush of current that could damage a motor while a VFD controls and can vary the speed of a motor.
In this article, we will look at:
- Internal workings of these devices
- How to determine which device you might want
- Look at some applications to better understand their differences
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

Let's first talk about the internal working of these two devices.
Internal Workings of a Soft Starter
A typical three-phase soft starter uses six Thyristors or Silicon Controlled Rectifiers, oriented in an anti-parallel configuration to start the electric motors smoothly.
A Thyristor is made up of 3 parts:
- Logic gate
- Cathode
- Anode
When an internal pulse is applied to the gate, it allows current to flow from Anode to Cathode which then sends current out to our motor.
When the internal pulses do not apply to the gate, the SCRs (Silicon Controlled Rectifier) are in the OFF state and therefore they restrict the current to the motor.
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

These internal pulses limit the applied voltage to the motor slowing down inrush current.
The pulses are sent based on ramp time so the current will be slowly applied to the motor. The motor, attached to the soft starter, will start up at a nice smooth current and top out at the preset maximum speed.
The motor will stay at that speed until we stop the motor where the soft starter will ramp down the motor in a very similar way as the ramp up.
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

Internal Workings of a VFD
VFDs have three main components:
- Rectifier
- Filter
- Inverter
The Rectifier acts like Diodes, takes the incoming AC voltage and changes it to DC voltage.
Next, the Filter uses Capacitors to clean the DC voltage making it a smoother incoming power.
Finally, the Inverter uses transistors to convert the DC voltage and sends the motor a frequency in Hertz. This frequency drives the motor to a specific RPM.
We can set the ramp up and down times just like in a soft starter.
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel

VFD or Soft Starter? Which One should I Choose?
From what we just covered, we can see that a VFD is basically a soft starter with speed control. So how do we know which device is needed for our application?
The decision on which device you choose comes down to how much control your application requires. There are other factors that we should consider in our decision.
1. Speed Control
If your application requires a large inrush of current but does not require speed control, then a soft starter is the best option. 
If speed control is required, then a VFD is a must. 
2. Price
Price can be a determining factor in a lot of real-world applications. Since a soft starter has fewer control features, the price is lower than a VFD.
3. Size
Finally, if the size of our device is a determining factor, soft starters are generally smaller than most of the VFDs.
Now, let's look at some real-world applications to help us see the difference between a VFD and a Soft Starter.
Application Example of VFDs and Soft Starters 
1. Water Treatment Facility
The first application will be a wastewater pump. A water treatment plant typically has a constant flow of water coming into the plant. Let's assume the demand for water exiting the plant is constant with the supply entering the plant.
Which device would be the best option?
That's right! A soft starter would be a great choice because in this application when starting the water pump there would be a large inrush of current on our motor that our soft starter could handle and gradually ramp up the pump.
Since the demand for water exiting the plant is the same as supply into the plant the speed of our pump would not vary.
However, if the demand for water exiting the plant raises or lowers, we would want to vary our speed making a VFD a better choice for the application.

2. Cooling Fan System
The next application we will look at is a cooling fan.
In this scenario, a cooling fan will turn on when the plant air temperature hits a high-temperature set-point.
Once the set-point is reached, the cooling fan will slow down to maintain the air temperature unless it drops below a low-temperature setpoint, where it will shut off.
However, if the temperature continues to rise and pass the high-temperature setpoint, the fan will need to move faster.
Which device would work best in this situation?
That's right! A VFD would be better than a soft starter because the speed of the fan will need to vary.
If our scenario was only turning the fan on or off based on temperature and not changing speed, then a soft starter would be a better option.
15HP 11kw 380V 50Hz AC Soft Starter for Control Panel


Summary
In closing, a VFD and a Soft Starter can do similar functions when it comes to ramp up or down a motor.
The main difference between the two is that a VFD can vary the speed of a motor while a soft starter only controls the starting and stopping of that motor.
When faced with an application, price and size are in the favor of a soft starter. A VFD is the better choice if speed control is required.
The good news is that if an existing application has a soft starter in place and speed control is later determined to be a requirement, a VFD can easily replace a soft starter. The opposite is true as well, a soft starter can replace a VFD.


 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR243177". Items marked "verified" are certified.

Watch Video
Watch Video
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.
WENZHOU JUNKE ELECTRIC CO., LTD.

About Our Factory & Business Background

Address
Tangaozhu West Village Liushi Yueqing Zhejiang
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CIF, DDP, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Swtich, Power Capacitor, Air Circuit Breaker, Single Meter Socket, Online Soft Starter, Power Factor Correction Device, Energy Meter, Distribution Panel, AC Contactor, Moulded Case Circuit Breaker

Our Industry Experience & Global Business Record

Export Year
2010-10-01
Main Markets
South America, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia

FAQ

What is the main difference between a VFD and a soft starter?
A VFD can vary the speed of a motor, while a soft starter only controls the starting and stopping.
When should I choose a soft starter over a VFD?
Choose a soft starter if your application requires large inrush current handling but does not need speed control.
Can a VFD replace an existing soft starter?
Yes, if speed control is later required, a VFD can easily replace a soft starter in an existing application.
What is the recommended starting limit for the motor?
It is recommended not to exceed 20 starting times per hour.
What types of motors are compatible with this device?
It is designed for squirrel-cage three-phase asynchronous motors.
What is the lead time for this product?
Peak season lead time is one month, while off-season lead time is within 15 workdays.
What payment methods are accepted?
We accept LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
What is the output current range?
The output current ranges from 22A to 1200A.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now