• Apfc Power Factor Correction Capacitors for Home Leading Power Factor
  • Apfc Power Factor Correction Capacitors for Home Leading Power Factor
  • Apfc Power Factor Correction Capacitors for Home Leading Power Factor
  • Apfc Power Factor Correction Capacitors for Home Leading Power Factor
  • Apfc Power Factor Correction Capacitors for Home Leading Power Factor
  • Apfc Power Factor Correction Capacitors for Home Leading Power Factor

Apfc Power Factor Correction Capacitors for Home Leading Power Factor

Theory: Electromagnetic Relay
Usage: Household Appliances Relay
Phase: 3
Electricity Type: Ac
Number of Pole: 3
Load: Micro Power Relay
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
RPCF
Protective Characteristics
Enclosed Rlay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Automatic Power Factor Controller PCB
Relay Control Signal
Power Supply
Power Transformer 230V~400V
Power Control
Relay
Power Sensor
CT Type
Power Factor Controller Function
Power Factor Less Send Signal to Capacitor
Display
LED/LCD
Over Voltage Setting
230V~500V
Port1
Shanghai
Port 2
Qingdao
Purchase Way
Market Supply
Transport Package
Carton
Specification
CE ROHS
Trademark
OEM
Origin
Zhejiang Yueqing
HS Code
8537909000
Production Capacity
100000PCS/ Month

Product Description

APFC power factor correction capacitors for home leading power factor 
The power factor approve state of user
To improve the utilization efficiency of electric transformer
Reducing line loss
To improve the voltage quality of power supply
 Specification
Item  Name   Low Voltage Pfr Automatic Power Factor Controller 
1 LED/LCD Display will show  
a.three-phase voltage,current, active power, reactive 
b.power factor and power network frequency, control parameter
2 Strong anti-interference ability can resist 2kv impulse test ,keep data 
3 You can revise control data sheet ,it will save data no power 
4 Auto analysis phase function 
5 Current get signal resistor less than 0.05Ω
6 Over voltage ,under voltage lack phase protection function 
7 Input way: static ,Dynamic ,compound 
8 Rated voltage AC 220V±10%  AC 380V±10%
9  Rated current AC 0-5A
10 Rated frequency 50Hz±5%
11 Sensitivity 100mA
12 COS φ Preset  0.80-0.99; step length 0.01; Factory preset 0.98 input and cutoff time
13 Input Delay dynamic state 100ms-30S; Static state 1-250S;Factory preset dynamic state 5S; 
static state 30S.
14 Over-voltage protection 230-260V; step length 1V; Return difference 6V  reset 240V,
15 Under-voltage protection 180V;return difference 6V
16 Auto Discriminating Phase ON/OFF; factory preset ON(Auto discriminating ON)
17 Reactive threshold OFF-4-100kvar; factory preset OFF (reactive threshold inefficiency)
18 CT variation 50/5A-3000/5A; step length 1; factory preset 500/5A
19 Capacitance capacity 0-99kvar factor preset of each branch 10kvar
20 Contact capacity dynamic state output of each branch DC12V×50mA
Static state output of each branch 380V×7A/200V×5A
21 size 113*113   138*138

   function 
Control signal: comprehensive control by using the power factor and reactive current of two physical quantities;
Step :step number selected by the user;
Data storage: after the loss of electricity parameter settings will not be lost, data save permanently;
Adaptability: automatically adapt to the distribution system of different parameters of the controller, does not need to provide the transformation ratio of current transformer and capacitor compensation capacity;
Overvoltage protection: the voltage is higher than the set value quickly over voltage, gradual resection capacitors have been put;
Strong antiinterference: unique design, crash, indiscriminately, indiscriminate cutting phenomenon can not occur in operationSwitching shocks: can prevent the small current load and over voltage critical values appear repeated switching;
High sensitivity: compensator can work normally in the input signal when the current is 0.10A;
Display error: input signal power of current 0.10A to 5A changes due tonumerical error measurement showed minimal;
The current identification: the controller can judge the sampling current polarity and automatic conversion.
Apfc Power Factor Correction Capacitors for Home Leading Power Factor
Apfc Power Factor Correction Capacitors for Home Leading Power Factor
Apfc Power Factor Correction Capacitors for Home Leading Power Factor
Apfc Power Factor Correction Capacitors for Home Leading Power Factor
Apfc Power Factor Correction Capacitors for Home Leading Power Factor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now