Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2010-10-01
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
  • Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator
Find Similar Products

Basic Info.

Model NO.
FZW38 -SF6
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Sf6
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB
Using Range
Outdoor
Insulate Medium
Sf6 Gas
Voltage
12/24/36kv
Transport Package
Wooden Package
Trademark
JUNKE
Origin
Wenzhou
Production Capacity
1000PCS/Month

Product Description

SF6 12/24/36KV Load Breaker switch Sectionalizer with polymer insulator
1, Overview JW‐12/24/36,is suitable for the rated voltage 12/24/36 kV,rated current 630A 50/60Hz power     grid open circuit,load current in closed Power system overload current. This load switch can separate those broken distribution line automatically.  With the latest techno logy, it has the newest electronic controller.The switch can be used by manual operation, electric operation and operation from a long distance. Electronic controller is   installed in a stainless   steel cabinet which is suitable for using under all kinds of climatic conditions. In addition, there   are some wired and wireless modem installed in the cabinet through which it can realize the   remote monitoring and control. Simple installation on column is convenient, fast, and also can re duce the construction cost.

2,The standard conditions of use      operating conditions for SF6 gas load switch to adapt to: 2.1  Ambient temperature 2.1.1 Ambient air temperature: upper limit +50 ° C, lower limit of ‐40 ºC. 2.2 Elevation does not exceed 1000m;2000m;3000m; 2.3 The pressure does not exceed 700pa (equivalent to wind speed of 34m / s) 2.4 Earthquake intensity: 8 degrees 2.5 Pollution class: class III, class IV.

3 Features 3.1 SF6 gas‐insulated 3.2   Drive pipe with large diversity 3.3   Visible open / closed status 3.4 Quick operation 3.4.1 operating mechanism with spring energy to ensure a quick closing and opening operation.   3.5 Can realize remote control 3.5.1 It is equipped with electronic controller, fit for in situ operation as well as FTU interface   console operation. 3.6 Rugged switch 3.6.1 The switch is made of proven durable, corrosion‐resistant materials (special used in   warships 304L stainless steel plate)which ensures that there is a very long service life (30 years),   and can be implement a series of operations.It has the ideal characteristics as a column   equipment. 3.7 Standard 3.7.1 Each switch before leaving the factory has been filled with SF6 gas, sealed, and test accordin g to IEC60265‐1 (1988), GB3804‐1990 standard.

Specifications:

Description 

JLB-12/24 SF6 load break switch is a HV electrical equipment of high reliability and maintenance-free, with rated voltage 12kV/24kV and rated frequency 50Hz, applicable for 10kV distribution line as load regulation & control as well as distribution automation system. There are two types for the product: manual and motor-driven type.

 

Technical Parameter

Item

Unit

Data

 

12kV

24kV

36kV

 

Rated Current

A

630

630

630

 

Rated Voltage

kV

12

24

26

 

Rated Insulation Level

1 min Power Frequency

Withstand

Voltage

Dry

42/49

50/65

70/90

 
 

Wet

34

55

65

 
 

Lightning Impulse

Withstand Voltage (Peak)

75/85

125/145

150/175

 
 

Rated Frequency

Hz

50/60

50/60

50/60

 

Rated Short-circuit Closing Current (Peak)

kA

50

63

63

 

Rated Short-time Withstand Voltage (4s)

20

25

25

 

Rated Peak Withstand Current

50

63

63

 

Rated Operating Voltage (Controller)

V

AC220

AC220

AC220

 

Auxiliary Circuit Rated Voltage

DC24

DC24

DC24

 

Mechanical Life

times

3000

5000

5000

 

SF6 Rated Air Pressure (20°C)

MPa

≤0.71

≤0.71

≤0.71

 

SF6 Rated Annual Leak Rate

%

≤0.5

 

Operation Mode

 

Spring Operation (Manual/Electric)

Sf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer InsulatorSf6 12/24/36kv Load Breaker Switch Sectionalizer with Polymer Insulator