Basic Info.

Model NO.
KCT split core CT
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Model
Kct-6,Kct-10,Kct-16,Kct-24,Kct-36
design Advantage
Clamp on Cts
Accuracy
0.5/1.0
Rated Input
5A-630A
Rated Output
0.33V(AC)or 0-500mA
Window Size
Check Specification Below
Insulation Resistance
DC500V/100mΩ Min
Frequency
50-2kHz
Dielectric Strength
2.5kv/1mA/1min
Operating Temp
-25ºC~75ºC
Transport Package
Export Carton
Specification
IEC 6044-1
Trademark
HEYI/ASCT
Origin
Zhejiang Provincechina
HS Code
8504311000
Production Capacity
100000 PCS/Month

Product Description

KCT Series Split Core Current Transformer 
 

               KCT range of split core current transformer have been specifically designed to be mini size which implement the installation of small space,clamp-on design could be easily fit around cables without breaking the circuit.An internal precision resistor across the secondary winding of the CTprovides a low safe voltage output.

                                          Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy
Applications:

Current measurement,monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and 
automation-control system.
Current,power and energy monitoring device.
Relay protection device.


 

Features:

The structure of the self-locking,safe,easy to install,portable
Wine inner window,allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installations
 Isolated plastic case recognized according to UL94-V0
Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs

 



Technique Indes:

 
 Electrical Parameter   Electrical Parameter 
 Frequency  50-2KHz  Case   Pa66/UL94-V0
 Rated Input   5A-630A  Bobbin  PA66
 Measuring range  10%In-120%In  Core  Ferrite. Silicon steel
 Rated Output  0.333V(AC)or 0- 500mA  Internal structure  Epoxy
 Ratio  ≤±1.0%  Construction  Tie
 Phase angle  ≤±60min   Operating Tem  -25ºC~75ºC
 Dielectric Strength  2.5KV/1mA/1min  Opeaating Humidity  ≤85%
 Insulation Resistance   DC500V/100MΩ min   Output Connection  UI1015 20AWG Wire(twinsted wire)3m





KCT-6

Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy
 

 MODEL  KCT-6
 Current Ratio  5A/2.5mA  10A/5mA  20A/10mA
 Primary Current(A)  5A  10A  20A
 Max.Current (A)  30A  30A  30A
 Output  2.5mA  5mA  10mA
 Load Resistance(Ω)  200Ω  100Ω  50Ω
 Class  0.5/1.0  0.5/1.0  0.5/1.0
 Turns Ratio   2000:1  2000:1  2000:1
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation





KCT-10

Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy


 

MODEL  KCT-10
 Current Ratio  5A/2.5mA  20A/10mA  60A/20mA  75A/25mA  1~75A/0.333V
 Primary Current(A)  5A  20A  60A  75A  1~75A
 Max.Current (A)  60A  60A  75A  75A  1~75A
 Output  2.5mA  10mA  20mA  25mA  333mV
 Load Resistance(Ω)  400Ω  100Ω  50Ω  20Ω  /
 Class  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0
 Turns Ratio   2000:1  2000:1  3000:1  3000:1  /
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation




KCT-16


Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy
 
MODEL  KCT-16
 Current Ratio  100A/33.3mA  100A/40mA  120A/40mA  200A/66.7mA  100~200A/0.333V
 Primary Current(A)  100A  100A  120A  200A  100~200A
 Max.Current (A)  120A  120A  120A  240A  /
 Output  33.3mA  40mA  40mA  66.7mA  333mV
 Load Resistance(Ω)  50Ω  50Ω  50Ω  20Ω  /
 Class  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0
 Turns Ratio   3000:1  2500:1  3000:1  3000:1  /
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation



KCT-24

Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy


 
MODEL  KCT-24
 Current Ratio  100A/40mA  200A/40mA  200A/66.7mA  400A/80mA  100~400A/0.333V
 Primary Current(A)  100A  200A  200A  400A  100~400A
 Max.Current (A)  150A  240A  240A  480A  480A
 Output  40mA  40mA  66.7mA  80mA  333mV
 Load Resistance(Ω)  50Ω  50Ω  50Ω  20Ω  /
 Class  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0
 Turns Ratio   2500:1  5000:1  3000:1  5000:1  /
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation
 
MODEL  KCT-24
 Current Ratio  100A/1A  150/1A  200A/1A  250A/5A(1A)  300A/5A(1A)  400A/5A(1A)
 Primary Current(A)  100A  150A  200A  250A  300A  400A
 Max.Current (A)  150A  180A  240A  300A  360A  480A
 Output  1A  1A  1A  5A(1A)  5A(1A)  5A(1A)
 Load Resistance(Ω)  1Ω  1Ω  1.5Ω  0.5(1.5)Ω  0.5(1.5)Ω  0.5(1.5)Ω
 Class  3.0  1.0  1.0  1.0(1.0)  1.0(1.0)  1.0(1.0)
 Turns Ratio   100:1  150:1  200:1  50:1(250:1)  60:1(300:1)  80:1(400:1)
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation




KCT-36

Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy

 
MODEL  KCT-36
 Current Ratio  300A/100mA  400A/40mA  500A/50mA  600A/60mA  300~600A/0.333V
 Primary Current(A)  300A  400A  500A  600A  300~600A
 Max.Current (A)  360A  480A  600A  720A  720A
 Output  100mA  40mA  50mA  60mA  333mV
 Load Resistance(Ω)  50Ω  50Ω  50Ω  50Ω  /
 Class  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0  0.5/1.0
 Turns Ratio   3000:1  10000:1  10000:1  10000:1  /
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation
 
MODEL  KCT-36
 Current Ratio  200A/5A(1A)  250/5A(1A)  300A/5A(1A)  400A/5A(1A)  500A/5A(1A)  600A/5A(1A)
 Primary Current(A)  200A  250A  300A  400A  500A  600A
 Max.Current (A)  240A  300A  360A  480A  600A  720A
 Output  5A(1A)  5A(1A)  5A(1A)  5A(1A)  5A(1A)  5A(1A)
 Load Resistance(Ω)  1Ω  1Ω  1.5Ω  0.5(1.5)Ω  0.5(1.5)Ω  0.5(1.5)Ω
 Burden(VA)  0.5(1.5)  0.5(1.5)  0.5(1.5)  1.5(2.5)  1.5(2.5)  1.5(2.5)
 Class  3.0(1.0)  1.0(1.0)  1.0(1.0)  1.0(0.5)  1.0(0.5)  1.0(0.5)
 Turns Ratio   40:1(200:1)  50:1(250:1)  60:1(300:1)  80:1(400:1)  100:1(500:1)  120:1(600:1)
 Protection Level  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P  7.5V0-P
 Insulation Category  CATIII
 Operating Condition -20ºC~+50ºC,≤85%RH,NO condensation,IN-house& Any direction installable
 Storage Condition -30ºC~+50ºC,≤85%RH,No condensation




Graph:

Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy




Real Picture:

                Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy
         
                 Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy  


Wring Method:

                   Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy
       
 
Installation method:


    Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy


  
Certifications:
 
                      Split Core Current Transformer AC Current Kct-6kct-10kct-16kct-24kct-36 High Accuracy


Advantages of Our:

      

1) CT Core:We will use the suitable core according to accuracy of requirement from customers, includes Silicon steel sheetFerriteAMD and Permalloy.
2) Lead Wire: It meets  UL1015 22AWG 600V 105°c (L=600mm). And we have 4 wire connectors, such as Wires plugs, Audio plugs, Power plugs and so on.
3) Some series of split core CT outer Case is Imported materials, PA. Brand is Dupont from USA
4) The plastic for packing is environmental and recyclable.
5) We also offer customers personal services contains OEM, ODM and OPM.


  
How to Order?
1. Please let us know what kind of model, color, poles and rated current etc.
2. Proforma invoice (PI) will be sent to you.
3. Please check and confirm the PI.
4. Once we confirmed the order, please pay it soon.
5. After full payment, all goods will be sent to you in 6-10 days as usual.
6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders.


Payment:
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment.


Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.

 
Warranty:
1. We provide 1 year warranty.
2. If the product is defective, please notify us within 3 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now