• 126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126
  • 126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126
  • 126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126
  • 126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126
  • 126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126

126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vacuum
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LW36-126
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, CB
Transport Package
Wooden Package
Trademark
JUNKE
Origin
Wenzhou
Production Capacity
1000PCS/Month

Product Description

126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126Main features
Adopt self-extinguish principle, small operating energy, light mechanical impact;
Use spring mechanism, its performance is not relevant to temperature, stable performance;
Optimized interrupter structure and movement curve of contact, high reliability on breaking current;
Reignite and restrike cannot occur under breaking capacitive current;
Optimized pole and frame design with higher capability to endure earthquake;
High reliability, long average normal service time, low maintenance cost;
Convenient installation and configuration in field, it takes only one day or two days;
Low operating noise, suit for residential area.:
Environmental conditions
Installation site
outdoor
Ambient temperature
-25ºC~+40ºC
Max. daily temperature difference
≤25ºC
Height above sea level
2000m(no limit for specified order)
Air humidity
Daily average:≤95%;
month average:≤90%;
Wind speed
≤34m/s
Solar radiation
≤0.1W/cm2(fine day, noon)
Earthquake intensity
horizontal:≤0.3g;vertical:≤0.15g
Icing thickness
≤10mm
Creepage distance
25mm/kV or 31mm/kV
Static load on terminal in Y-direction
1250N
Static load on terminal in X-direction
750N
Static load on terminal in Z-direction
1000N
Main Technical data
No.
                                               Items
       Unit
        Parameter
1
Rated voltage
kV
126
2
Rated power frequency withstand voltage(1min)
Phase-to-phase
Phase-to-ground
kV
230
fracture
kV
230+73*
3
Rated lightning impulse withstand voltage
Phase-to-phase
Phase-to-ground
kV
550
fracture
kV
550+103*
4
Power frequency withstand voltage(5min)under SF6 zero-gauge pressure
kV
95
5
Rated frequency
Hz
50
6
Rated current
A
3150
7
Rated short circuit breaking current
kA
40
8
First-pole-to-clear factor
 
1.5
9
Rated short circuit breaking current
(DC component)
 
More than 41%
10
Rated short circuit making current (peak)
kA
100
11
Rated short time withstand current(rms)
kA
40
12
Rated peak withstand current
kA
100
13
Rated short circuit duration
s
4
14
Rated out-of-phase breaking current
kA
3(OP1) ,10(OP2)
15
Short range breaking current
kA
36;30
16
Wrong-phase earthing fault
breaking current
kA
34.8
17
Rated line charging switching current
A
31.5
18
Full capacity breaking time without check and repair
Times
20 or rated current breaking times:3000
19
Rated operating sequence
 
O-0.3s-CO-180s-CO
20
Rated SF6 pressure (20ºC gauge)
MPa
0.6
21
Alarm/Lock pressure(20ºC gauge)
MPa
0.55/0.50
22
SF6 annual leakage rate
%/Y
≯0.5
23
Gas moisture content
Check value
after hand over
μL/L
≯150
Allowed service
value
μL/L
≯300
24
Resistance of the main circuit
μΩ
≤35
25
Mechanical life
Time
6000
26
Radio interference level (1.1Ur/)
μV
≯500
27
Allowed partial discharge intensity(1.2Ur)
pC
≤5
28
Noise(distance from sound source:horizontality:2m,height:1.5m)
dB
90

126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126126kv1250A Outdoor Six Sulfur Hexafluoride Outdoor High Voltage Vacuum Circuit Breaker Lw36-126
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now